HUCEEN CPU SR30 AC/DC/RLY

Description

E7 200Smart CPU Standard Edition,CPU SR30 Relay,18DI/12DO,1*RJ45,2*RS485, Expandable to 6IO

CPU SR30 AC/DC/RLY Specifications

Model No: SR30 AC/DC/RLY
Article No: E7 288-1SR30-0AA1
Description: Standard CPU SR30, Relay
Conventional Norm: Not specified
Dimensions (WxHxD): 110 × 100 × 81 mm
Power Consumption: 23W
Available Current (SM Bus): Max. 1400mA
Available Current (24V DC): Max. 300mA

CPU Features

  • Program Memory: 18 KB
  • Data Memory: 12 KB
  • Retentive Memory: 10 KB
  • Data Preservation: Permanent
  • Built-in I/O:
    • Digital Inputs/Outputs: 18 inputs / 12 outputs
  • Process Image Size: 256-bit Input (I) / 256-bit Output (Q)
  • Analog Image: 56 words Input (AI) / 56 words Output (AQ)
  • Expansion Modules Allowed: Up to 6 modules
  • High-Speed Counters (Total): 6
    • Single Phase: 4 @ 200KHz + 2 @ 30KHz
    • Quadrature Phase: 2 @ 100KHz + 2 @ 20KHz
  • Pulse Output: None
  • Timer:
    • Non-Holding (TON, TOF): 192
    • Holding: 64
  • Counters: 256
  • Bit Memory (M): 256 bits
  • Cycle Interrupt: 2 (T32 and T96) with 1ms resolution
  • Interrupt Edge: 4 Up and 4 Down
  • Real-Time Clock: Typically 7 days, at least 6 days at 25°C
  • Memory Card: Supported
  • Signal Expansion Board: Supported

Performance/Processing Time:

  • Boolean: 0.35 µs/instruction
  • Moving Word Operations: 1.2 µs/instruction
  • Floating Point: 1.7 µs/instruction

Communications Built-in

  • Ports:
    • Ethernet: 1
    • Body Serial Port: 2 (DB9-RS485)
    • DB Board Serial Port: 1 (CM01-RS485-RS232)
  • HMI Connections:
    • Ethernet: 8 connections
    • Serial Port: 4 connections
  • Programming (PG): 1 connection
  • Ethernet (CPU PUT/GET): 8 clients and 8 servers connections
  • Open Type Communication: 8 active and 8 passive connections
  • Data Transmission Rate:
    • Ethernet: 10/100 Mb/s
    • RS485 System Protocol: 9600, 19200, and 187500 b/s
    • RS485 Free Port: 1200 to 115200 b/s
  • Isolation:
    • Ethernet: Transformer isolation, 1500VDC
    • RS485: None
  • Cable Type:
    • Ethernet: CAT5e Shielded cable
    • RS485: PROFIBUS Network cable

Power

  • Input Voltage: 85-264V DC
  • Input Current (CPU only):
    • 130mA (without 300mA power supply output of the sensor) at 120V AC
    • 250mA (with 300mA power supply output of the sensor) at 120V AC
    • 80mA (without 300mA power supply output of the sensor) at 240V AC
    • 150mA (with 300mA power supply output of the sensor) at 240V AC
  • Input Current (Includes CPU and all expansion accessories): 300mA at 120V AC, 190mA at 240V AC
  • Inrush Current (Max): 8.9A at 264V DC
  • Sensor Voltage: 20.4-28.8V DC
  • Isolation:
    • Input to Logic: 1500V AC for 1 minute
    • Sensor to Logic: Not isolated

Digital Input

  • Number of Inputs: 18
  • Input Type: Sinking / Sourcing type (IEC type 1 sinking, except for I0.0 to I0.3)
  • Allowable Continuous Voltage: Max. 30V DC
  • Surge Voltage (Max): 35V DC, lasting 0.5s
  • Logic 1 Signal (Min): 15V DC when the current is 2.5mA
  • Logic 0 Signal (Max): 5V DC when the current is 1mA
  • Optical Isolation (Field Side and Logic Side): 500V AC lasting 1 minute
  • Isolation Group: 1
  • Filter Time: Each channel can be separately selected (I0.0 to I1.5): 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 µs; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms. For points I1.6 and larger: 0, 6.4, 12.8 ms

Digital Output

  • Number of Outputs: 12
  • Output Type: Relay, dry contact
  • Voltage Range: 5-30V DC or 5-250V AC
  • Surge Current (Max): 7A when powered on
  • Rated Current per Point (Max): 2.0A
  • Switching Frequency (Max): Not recommended
  • Turn-on Delay (Qa.0-Qa.3): Up to 10ms
  • Turn-off Delay (Qa.4-Qb.3): Up to 10ms
  • Optical Isolation (Field Side and Logic Side): 500V AC lasting 1 minute
  • Contact Lifetime:
    • Non-loaded: 10,000,000 cycles
    • Rated Load: 10,000 cycles

This specification covers all major details of the CPU SR30 AC/DC/RLY, including its communication features, power requirements, input/output characteristics, and performance capabilities. If you need further clarification or specific details, feel free to ask!